Skip links

Silicone Interlocking Overhead Line Cover

Home / Silicone Interlocking Overhead Line Cover

Gala Silicone Interlocking Overhead Line Covers are made from high quality non-tracking silicone rubber that are designed for field installation over bare conductors. These covers provide a layer of electrical insulation for Phase-to-Phase and Phase-to-Ground protection from bird and animals. The GSIOC provides electrical insulation, UV resistance and tracking resistance. Provide Insulation upto 33 kV.

Features and Benefits

Diagram

Selection Chart – GSIOC-M (Upto 12kV)

Selection Chart – GSIOC-M (Upto 12kV)
Gala Code Conductor Dia. (mm) Thickness (mm) Packaging (Mtr./Roll)
GSIOC-M 12 Up to 12 2 15
GSIOC-M 15 Up to 15 2 15
GSIOC-M 18 Up to 18 2 15
GSIOC-M 20 Up to 20 2 15
GSIOC-M 24 Up to 24 2 15

Selection Chart – GSIOC-H ( Upto 33kV )

Selection Chart – GSIOC-H (Upto 12kV)
Gala Code Conductor Dia. (mm) Thickness (mm) Packaging (Mtr./Roll)
GSIOC-H 12 Up to 12 2.7 15
GSIOC-H 15 Up to 15 2.7 15
GSIOC-H 18 Up to 18 2.7 15
GSIOC-H 20 Up to 20 2.7 15
GSIOC-H 24 Up to 24 2.7 15

Selection Chart – GSDIOC ( Upto 33kV )

Selection Chart – GSDIOC ( Upto 33kV )
Gala Code Conductor Dia. (mm) Thickness (mm) Packaging (Mtr./Roll)
GSDIOC-10 Up to 10 3.8 15

Technical Specification

Technical Specification*
PROPERTIES TEST METHOD TYPICAL VALUE
Physical
Tensile Strength ASTM D638 4 N/mm² (Min.)
Elongation ASTM D638 200% (Min.)
Density ASTM D792 1.10 – 1.45 gm/cm³
Hardness ASTM D2240 65 ± 5 Shore A
Low Temp. Flexibility (-20°C / 4 Hrs.) ASTM D2671 No Cracking
Water Absorption (24 Hrs @ 23°C) ASTM D570 0.5% (Max.)
Thermal
Thermal Ageing ASTM D2671 150°C for 168 Hrs.
Tensile Strength (After Ageing) ASTM D638 3 N/mm² (Min.)
Elongation (After Ageing) ASTM D638 100% (Min.)
Electrical
Dielectric Strength ASTM D149 21 kV/mm (Min.)
Volume Resistance ASTM D257 1 × 10¹⁰ Ohm·cm (Min.)
Tracking & Erosion Resistance ASTM D2303 No tracking or erosion to top surface or flame failure after:
• 1 hr at 2.5 kV
• 1 hr at 2.75 kV
• 1 hr at 2.5 kV
• 1 hr at 3.0 kV
• 20 min at 3.25 kV

* The above mentioned values are typical analytical values obtained on material when tested as per applicable standards under controlled laboratory conditions and should not be construed as product specifications.