Skip links

Cable Terminal Protector(GTPE-500)

Home / Cable Terminal Protector(GTPE-500)

Gala Elbow Terminal Protector will be used in the cable entry boxes with any types of indoor terminations, where the phase to phase clearance is less & having possibility of air flash over, where the air will not give the adequate insulation level. This Product will act as a barrier and minimize the chance of flashovers.
Components are manufactured from the special formulation of EPDM rubber having good UV resistance, track resistance, insulation & mechanical properties. it is a moulded component and can be used on epoxy bushing. Each component is factory tested to provide reliability.
The Terminal protector GTPE-500 can be used in the Ring main units having Bushing of type interface. This has been designed to exceed Minimum industry test standards and have dielectric strength more than 15kV / mm. The Terminal Protector GTPE-500 will give the adequate insulation and easy to install as it is one piece design. This Product is not a touch proof Product.

Features & Benefits

Diagram

Selection Chart – Right Angle Boot

Selection Chart – Right Angle Boot
Product Code Application Voltage(kV) Bushing Center Distance
GTPE-1 12 95

Technical Specification

Technical Specification
Test Rated Voltage 12 kV Rated Voltage 24 kV
AC High Voltage Withstand Test for 1 Min Duration 28 kV 50 kV
Impulse Withstand Test 75 kV 125 kV
Test Description Recorded Value Test Method
Physical
Tensile Strength 10 N/mm² (MPa) (min.) ASTM D638
Ultimate Elongation 200% (min.) ASTM D638
Water Absorption 0.5% (max.) ASTM D570
Hardness 35 ± 5 Shore D ASTM D2240
Thermal
Continuous Temperature Limit -40°C to +115°C IEC 216
Electrical
Dielectric Strength 15 KV/mm. (min.) ASTM D149
Volume Resistivity 1 x 10¹³ Ohm.cm (min.) ASTM D257
Dielectric Constant 5 (max.) ASTM D150

Certificates

FAQs

1. What is a Screened Separable Connector?

A Screened Separable Connector is a medium-voltage cable accessory used to connect power cables to transformers, switchgear, or other equipment. It is fully screened and separable, allowing safe installation, disconnection, and maintenance.

They are commonly used for 3.6 kV to 36 kV medium-voltage applications, depending on the connector design and standards.

Related Products

Polyolefin Overhead Line Cover

Polyolefin Overhead Line Cover

Polyolefin Overhead Line Cover

109+

Countries

Served

40+

Years

In Industry

1250+

Kw

Solar Generative

225000

Area

Sq ft

This site is registered on portal.liquid-themes.com as a development site. Switch to production mode to remove this warning.