Tamper Proof End Seal
Products
- Heat Shrinkable Joints & Terminations
- Insulation Enhancement Product
- Screened Separable Connectors
- Heat Shrinkable Moulded Shapes
-
Heat Shrink Tubes / Sleeves
- Advantages Of Heat Shrink Tubing
- Thin Wall Tubes
- GDW : Dual Wall Tubing
- Medium/Heavy Wall Tubes-Commercial
- Heat Shrink Co-extruded Tubing Premium Quality
- Red Insulation Tubes
- Non Tracking Tubes
- Busbar Sleeves
- Stress Control Tube
- Non Tracking Tubes
- Integrated Stress Control Tube-GVOT Tube
- Heat Shrink Double Layer Tube-GDTL Tube
- High Shrink Ratio Heat Shrink Tube
-
Switchgear Insulation Products
- Barrier Board Sheet
- End Sealing Kit for Extensible RMU/GIS Bushing
- Heat Shrink Bus Bar Sleeve
- Bus Bar Insulating Shrouds
- Bus Bar Insulating Shrouds Polyolefin
- Bus Bar End Caps
- Thin wall tube wire marking
- Heat Shrink Tape (Bustape)
- Insulation for Circuit Breakers
- Busbar Sleeve for 66 kV
- Bushing Boot
- Non Shrinkable High Voltage Tape
- Heat Shrinkable Gland
- Cable Sealing & Repair Products
- Silicone Overhead Line Cover
- Polyolefin Overhead Line Cover (Insulcover)
- Overhead Line Tube (Insulcover)
- Pipeline / Corrosion / Cathodic Protection Products
- Pole Protection Products
- Wire Harness Products
- New Products
- Miscellaneous
Tamper Proof End Seal is Heat Shrink End Cap, used to seal the ends of all types of Cables & to protect it from ingress of water/moisture. The caps are manufactured from high quality cross linked polyolefin material.
Compatible with most commonly used 36 Kv Cable Joints i.e. XLPE, PVC, PILC or Rubber Sheathed Cable.
Hot Melt adhesive lining provides permanent seal on irregular cable sheaths.
Excellent resistance to weathering, moisture, contamination and adverse environmental conditions, according to IP 68 (Ingress Protection).
Features & Benefits
- Permanent Foolproof Seal to the Cable end.
- Can not be tampered, removed or re-used.
- Can be considered as Factory fitted Cable end seal.
- Can be considered as Factory fitted Cable end seal.
- Customised Logo Printing with Special High Performance Non Removable Ink.
- Warranty of Cable length can be considered as void in case Cable is found without Tamper Proof end seal.
- Avoids unwanted customer claims for Shortage/Pilferage of Cable length.
- Valved End caps (V) available for pressurized application for Telecom cables.
- Special Relief valved End Caps (RV) available for degassing application in High Voltage Power cables.
Diagram
Selection Chart
| CODE NO. | Ds (Min.) | Df (Max.) | Ls (Min.) | Tf (±10%) | CABLE RANGE |
|---|---|---|---|---|---|
| GEC 001S | 6 | 22 | 52 | 2.0 | 2 – 4 |
| GEC 001SA | 8 | 22 | 52 | 2.0 | 4 – 6 |
| GEC 001 | 12 | 44 | 40 | 2.3 | 4 – 8 |
| GEC 001L | 12 | 45 | 82 | 2.3 | 4 – 8 |
| GEC 001 A | 14 | 43 | 82 | 2.3 | 4 – 11 |
| GEC 001 AL | 14 | 45 | 82 | 2.3 | 4 – 11 |
| GEC 101 | 20 | 75 | 55 | 2.3 | 8 – 16 |
| GEC 101 L | 20 | 87 | 52 | 2.5 | 8 – 16 |
| GEC 101 A | 25 | 85 | 52 | 2.5 | 8 – 20 |
| GEC 101 AL | 25 | 87 | 52 | 2.5 | 8 – 20 |
| GEC 102 | 30 | 117 | 52 | 2.5 | 12 – 26 |
| GEC 102 A | 35 | 117 | 52 | 2.5 | 12 – 30 |
| GEC 102 AL | 35 | 110 | 52 | 2.5 | 12 – 30 |
| GEC 201 | 40 | 159 | 90 | 3.3 | 16 – 35 |
| GEC 201 L | 40 | 151 | 120 | 3.3 | 16 – 35 |
| GEC 201 A | 45 | 159 | 90 | 3.3 | 16 – 40 |
| GEC 201 AL | 45 | 151 | 120 | 3.3 | 16 – 40 |
| GEC 301 | 55 | 251 | 253 | 3.8 | 25 – 47 |
| GEC 301 L | 55 | 251 | 170 | 3.8 | 25 – 47 |
| GEC 301 A | 63 | 251 | 253 | 3.8 | 25 – 55 |
| GEC 301 AL | 63 | 251 | 170 | 3.8 | 25 – 55 |
| GEC 401 | 75 | 351 | 404 | 4.0 | 35 – 68 |
| GEC 401 L | 75 | 351 | 804 | 4.0 | 35 – 68 |
| GEC 401 A | 85 | 361 | 404 | 4.0 | 36 – 78 |
| GEC 401 AL | 85 | 351 | 804 | 4.0 | 36 – 78 |
| GEC 501 | 100 | 451 | 604 | 4.0 | 45 – 90 |
| GEC 501 L | 100 | 452 | 804 | 4.0 | 45 – 90 |
| GEC 501 A | 120 | 451 | 604 | 4.0 | 45 – 110 |
| GEC 501 AL | 120 | 452 | 804 | 4.0 | 45 – 110 |
| GEC 601 | 130 | 601 | 554 | 4.6 | 64 – 120 |
| GEC 701 | 154 | 601 | 654 | 4.6 | 70 – 145 |
| GEC 801 | 190 | 1252 | 204 | 4.0 | 140 – 165 |
| GEC 901 | 310 | 1202 | 207 | 4.0 | 140 – 280 |
| GEC 1001 | 400 | 2042 | 206 | 6.0 | 230 – 360 |
| GEC 1101 | 500 | 2002 | 206 | 6.0 | 230 – 460 |
Technical Specification
| PROPERTIES | VALUE | STANDARD |
|---|---|---|
| Physical | ||
| Tensile Strength | 12 N/mm² (MPa) (Min.) | ASTM D638 |
| Ultimate Elongation | 350% (Min.) | ASTM D638 |
| Density | 1.05 ± 0.2 gm/cm³ | ASTM D792 |
| Hardness | 45 ± 10 Shore D | ASTM D2240 |
| Water Absorption | 0.2% (Max.) | ASTM D570 |
| Thermal | ||
| Accelerated Ageing | (120°C for 500 Hrs) | ASTM D2671 |
| Tensile Strength | 11 N/mm² (MPa) (Min.) | ASTM D638 |
| Ultimate Elongation | 300% (Min.) | ASTM D638 |
| Low Temp. Flexibility (-40°C / 4 Hrs.) | No Cracking | ASTM D2671 |
| Heat Shock (250°C / 30 Min.) | No Cracking or Flowing | ESI 09-11 |
| Shrink Temperature | 125°C | IEC 216 |
| Continuous Temperature Limit | -40°C to +100°C | IEC 216 |
| Electrical | ||
| Dielectric Strength | 12 kV/mm (Min.) | ASTM D149 |
| Volume Resistivity | 1 × 10¹⁴ Ohm.cm (Min.) | ASTM D257 |
| Dielectric Constant | 5 (Max.) | ASTM D150 |
Certificates





FAQs
1. What is a Screened Separable Connector?
A Screened Separable Connector is a medium-voltage cable accessory used to connect power cables to transformers, switchgear, or other equipment. It is fully screened and separable, allowing safe installation, disconnection, and maintenance.
2. What voltage levels are Screened Separable Connectors used for?
They are commonly used for 3.6 kV to 36 kV medium-voltage applications, depending on the connector design and standards.
3. Where are Screened Separable Connectors typically used?
Related Products
Polyolefin Overhead Line Cover
Polyolefin Overhead Line Cover
Polyolefin Overhead Line Cover
Enquiry
109+
Countries
Served
40+
Years
In Industry
1250+
Kw
Solar Generative