Cold Shrink Breakout
Home / Cold Shrink Breakout
Products
- Heat Shrinkable Joints & Terminations
- Insulation Enhancement Product
- Screened Separable Connectors
- Heat Shrinkable Moulded Shapes
-
Heat Shrink Tubes / Sleeves
- Advantages Of Heat Shrink Tubing
- Thin Wall Tubes
- GDW : Dual Wall Tubing
- Medium/Heavy Wall Tubes-Commercial
- Heat Shrink Co-extruded Tubing Premium Quality
- Red Insulation Tubes
- Non Tracking Tubes
- Busbar Sleeves
- Stress Control Tube
- Non Tracking Tubes
- Integrated Stress Control Tube-GVOT Tube
- Heat Shrink Double Layer Tube-GDTL Tube
- High Shrink Ratio Heat Shrink Tube
-
Switchgear Insulation Products
- Barrier Board Sheet
- End Sealing Kit for Extensible RMU/GIS Bushing
- Heat Shrink Bus Bar Sleeve
- Bus Bar Insulating Shrouds
- Bus Bar Insulating Shrouds Polyolefin
- Bus Bar End Caps
- Thin wall tube wire marking
- Heat Shrink Tape (Bustape)
- Insulation for Circuit Breakers
- Busbar Sleeve for 66 kV
- Bushing Boot
- Non Shrinkable High Voltage Tape
- Heat Shrinkable Gland
- Cable Sealing & Repair Products
- Silicone Overhead Line Cover
- Polyolefin Overhead Line Cover (Insulcover)
- Overhead Line Tube (Insulcover)
- Pipeline / Corrosion / Cathodic Protection Products
- Pole Protection Products
- Wire Harness Products
- New Products
- Miscellaneous
❮
❯
×
Gala Cold Shrink Breakout are factory expanded and assembled onto a removable core. It provides sealing protection or multi core cable crutch. The insulating cable breakout is made of high quality EPDM Rubber which does not contain chloride or sulfur. It covers wide range of cable sizes.
Features and Benefits
- Simple and fast installation, no tools required.
- Accommodates a wide range of cable sizes.
- Seals tight, retains resiliency for years.
- Good abrasion resistance.
- Water resistance.
- No mastic or tape required.
- Resists acids and alkalis.
- Resists ozone.
- No training required for installation.
- Resists fungus.
- Good thermal stability.
- Excellent wet electrical properties.
- Tough rubber formulation withstands backfilling.
- Operating temperature range -40 °C to 105°C
- Water resistance, meets the water seal requirements of ANSI C119.1
- No torches or heat required.
Diagram
Selection Chart
Selection Chart
| Code No. | No of Core | Ds (min) | Application Range | ds (min.) | Application Range | Lf (Max.) | lf (Max.) |
|---|---|---|---|---|---|---|---|
| GCEB2 – 1 | 2 | 47 | Ø17 – Ø30 | 20 | Ø10 – Ø14 | 50 | 30 |
| GCEB2 – 2 | 2 | 65 | Ø23 – Ø45 | 25 | Ø12 – Ø17 | 65 | 30 |
| GCEB4 – 1 | 4 | 60 | Ø24 – Ø40 | 20 | Ø10 – Ø14 | 50 | 30 |
| GCEB4 – 2 | 4 | 70 | Ø32 – Ø50 | 25 | Ø12 – Ø17 | 65 | 30 |
Technical Specification
Technical Specification
| Properties | Test Methods | Typical Value |
|---|---|---|
| Colour | Visual | Black |
| 300% Modulus | ASTM D-412 | 3.3 MPa |
| Ultimate Tensile | ASTM D-412 | 9.6 MPa |
| Ultimate Elongation | ASTM D-412 | 750% |
| Die C Tear | ASTM D-624C | 26.3 KN/m |
| Fungus Resistance | ASTM G-21 | 28 Days exposure no growth |
| Moisture Absorption 7 days @ 90°C H₂O | Internal Method | Wt. Gain 1.8% |
| Dielectric Strength | ASTM D149 | 14.3 kV/mm |
Certificates





FAQs
1. What is a Screened Separable Connector?
A Screened Separable Connector is a medium-voltage cable accessory used to connect power cables to transformers, switchgear, or other equipment. It is fully screened and separable, allowing safe installation, disconnection, and maintenance.
2. What voltage levels are Screened Separable Connectors used for?
They are commonly used for 3.6 kV to 36 kV medium-voltage applications, depending on the connector design and standards.
3. Where are Screened Separable Connectors typically used?
Related Products
Polyolefin Overhead Line Cover
Polyolefin Overhead Line Cover
Polyolefin Overhead Line Cover
Enquiry
109+
Countries
Served
40+
Years
In Industry
1250+
Kw
Solar Generative
225000
Area
Sq ft