Skip links

Cold Shrink Tubing - EPDM

Home / Cold Shrink Tubing – EPDM

Gala Cold Shrink Tube are open ended, tubular rubber sleeves that are factory expanded and assembled onto a removable core. The core is removed after the tube has been position for installation over and inline connection, terminal lug etc. allowing the tube to shrink and form a water resistance seal. The insulating tube is made of high quality EPDM Rubber which does not contain chloride or sulfur. Seven diameter sizes will cover range of cable upto 1100 volts for copper and aluminium conductor upto 1000 Sq. mm.

Features and Benefits

Diagram

Selection Chart

Selection Chart
Part Number / Size Supplied I.D. (mm) Recovered I.D. (mm) Recovered Wall Thickness (mm) Spools Mtr./Spool
GPTFE 1.0/0.6 1.0 0.6 0.20 200
GPTFE 1.5/0.9 1.5 0.9 0.20 200
GPTFE 2.0/1.3 2.0 1.3 0.20 200
GPTFE 2.5/1.5 2.5 1.5 0.20 200
GPTFE 3.0/1.8 3.0 1.8 0.20 200
GPTFE 3.5/2.0 3.5 2.0 0.20 100
GPTFE 4.0/2.5 4.0 2.5 0.25 100
GPTFE 4.5/2.8 4.5 2.8 0.25 100
GPTFE 5.0/3.0 5.0 3.0 0.25 100
GPTFE 6.0/3.8 6.0 3.8 0.25 100
GPTFE 7.0/4.0 7.0 4.0 0.25 100
GPTFE 8.0/4.8 8.0 4.8 0.25 1
GPTFE 9.0/5.0 9.0 5.0 0.30 1
GPTFE 10.0/5.8 10.0 5.8 0.30 1
GPTFE 11.0/6.4 11.0 6.4 0.30 1
GPTFE 12.0/7.0 12.0 7.0 0.30 1
GPTFE 13.0/7.5 13.0 7.5 0.35 1
GPTFE 14.0/8.0 14.0 8.0 0.35 1
GPTFE 15.0/8.5 15.0 8.5 0.40 1
GPTFE 16.0/9.0 16.0 9.0 0.40 1

*All dimensions are in mm. d,D : Internal Diameter.

Technical Specification

Technical Specification
Properties Test Methods Typical Value
Colour Visual Black
300% Modulus ASTM D-412 3.3 MPa
Ultimate Tensile ASTM D-412 9.6 MPa
Ultimate Elongation ASTM D-412 750%
Die C Tear ASTM D-624C 26.3 KN/m
Fungus Resistance ASTM G-21 28 Days exposure no growth
Moisture Absorption 7 days @ 90°C H₂O Internal Method Wt. Gain 1.8%
Dielectric Strength ASTM D149 14.3 kV/mm

Certificates

FAQs

1. What is a Screened Separable Connector?

A Screened Separable Connector is a medium-voltage cable accessory used to connect power cables to transformers, switchgear, or other equipment. It is fully screened and separable, allowing safe installation, disconnection, and maintenance.

They are commonly used for 3.6 kV to 36 kV medium-voltage applications, depending on the connector design and standards.