Heat Shrink PTFE Tubings are made from High Quality Teflon material. These tubes are ideal solution for industries such as automotive, aerospace, fiber optics, food, and medical, etc. Teflon PTFE tubing resists corrosion, reduces weight, creates nonstick surfaces, and reduces abrasion.
The PTFE tubes are also ideal for insulating, terminating, moisture sealing, splicing, wire bundling, and electrical applications.
PTFE heat shrink tubing 1.7:1 offers the ultimate performance with the highest continuous working temperature of all.

Features and Benefits

Diagram

Selection Chart

Selection Chart
Part Number / Size Supplied I.D. (mm) Recovered I.D. (mm) Recovered Wall Thickness (mm) Spools Mtr./Spool
GPTFE 1.0/0.6 1.0 0.6 0.20 200
GPTFE 1.5/0.9 1.5 0.9 0.20 200
GPTFE 2.0/1.3 2.0 1.3 0.20 200
GPTFE 2.5/1.5 2.5 1.5 0.20 200
GPTFE 3.0/1.8 3.0 1.8 0.20 200
GPTFE 3.5/2.0 3.5 2.0 0.20 100
GPTFE 4.0/2.5 4.0 2.5 0.25 100
GPTFE 4.5/2.8 4.5 2.8 0.25 100
GPTFE 5.0/3.0 5.0 3.0 0.25 100
GPTFE 6.0/3.8 6.0 3.8 0.25 100
GPTFE 7.0/4.0 7.0 4.0 0.25 100
GPTFE 8.0/4.8 8.0 4.8 0.25 1
GPTFE 9.0/5.0 9.0 5.0 0.30 1
GPTFE 10.0/5.8 10.0 5.8 0.30 1
GPTFE 11.0/6.4 11.0 6.4 0.30 1
GPTFE 12.0/7.0 12.0 7.0 0.30 1
GPTFE 13.0/7.5 13.0 7.5 0.35 1
GPTFE 14.0/8.0 14.0 8.0 0.35 1
GPTFE 15.0/8.5 15.0 8.5 0.40 1
GPTFE 16.0/9.0 16.0 9.0 0.40 1

*All dimensions are in mm. d,D : Internal Diameter.

Technical Specification

Technical Specification
PROPERTIES VALUE STANDARD
Physical
Tensile Strength 19 N/mm² (Mpa) (Min.) ASTM D638
Ultimate Elongation 200% (Min) ASTM D638
Flammability Pass UL224 VW1
Low Temperature Flexibility (-45°C for 4 hrs) No Cracking ASTM D2671
Heat Shock (250°C for 30 min.) No cracking or flowing ESI 09-11
Dielectric Strength 30 kV/mm (Min) ASTM D149
Volume Resistivity 1 × 10¹⁴ Ohm.cm (Min) ASTM D257

Certificates

FAQs

1. What is a Screened Separable Connector?

A Screened Separable Connector is a medium-voltage cable accessory used to connect power cables to transformers, switchgear, or other equipment. It is fully screened and separable, allowing safe installation, disconnection, and maintenance.

They are commonly used for 3.6 kV to 36 kV medium-voltage applications, depending on the connector design and standards.