Heat Shrink Cable Repair Sleeves
Products
- Heat Shrinkable Joints & Terminations
- Insulation Enhancement Product
- Screened Separable Connectors
- Heat Shrinkable Moulded Shapes
-
Heat Shrink Tubes / Sleeves
- Advantages Of Heat Shrink Tubing
- Thin Wall Tubes
- GDW : Dual Wall Tubing
- Medium/Heavy Wall Tubes-Commercial
- Heat Shrink Co-extruded Tubing Premium Quality
- Red Insulation Tubes
- Non Tracking Tubes
- Busbar Sleeves
- Stress Control Tube
- Non Tracking Tubes
- Integrated Stress Control Tube-GVOT Tube
- Heat Shrink Double Layer Tube-GDTL Tube
- High Shrink Ratio Heat Shrink Tube
-
Switchgear Insulation Products
- Barrier Board Sheet
- End Sealing Kit for Extensible RMU/GIS Bushing
- Heat Shrink Bus Bar Sleeve
- Bus Bar Insulating Shrouds
- Bus Bar Insulating Shrouds Polyolefin
- Bus Bar End Caps
- Thin wall tube wire marking
- Heat Shrink Tape (Bustape)
- Insulation for Circuit Breakers
- Busbar Sleeve for 66 kV
- Bushing Boot
- Non Shrinkable High Voltage Tape
- Heat Shrinkable Gland
- Cable Sealing & Repair Products
- Silicone Overhead Line Cover
- Polyolefin Overhead Line Cover (Insulcover)
- Overhead Line Tube (Insulcover)
- Pipeline / Corrosion / Cathodic Protection Products
- Pole Protection Products
- Wire Harness Products
- New Products
- Miscellaneous
Heat Shrink Cable Repair Sleeves is manufactured from High Quality Cross-linked polyolefin material. Heat Shrink Cable Repairing Sleeve is an adhesive lined, wraparound heat shrink that can be easily applied without the need for disconnection. It provides superior environmental sealing, rugged mechanical protection and high performance electrical insulation.
Features and Benefits
- Provides permanent waterproof barrier & environmental seal.
- Shrink ratio 3:1.
- Flame retardant and self-extinguishing.
- Chemical, copper corrosion and fungus resistance.
- Shut down of system not required for repair.
- Hotmelt adhesive provides complete environmental sealing and insulation according to IP 68 (Ingress Protection).
- High resistance to UV rays, chemicals, corrosion, fungus, etc.
- Stocking only a few sizes will fit most repair needs.
- Custom dimensions available on request.
Selection Chart
| Gala Code | Cable OD | Length | Overlap Length |
|---|---|---|---|
| (mm) | (mm) | (mm) | |
| GMRS-19 | 5 – 10 | 100 / 200 / 300 | ≥ 25 |
| GMRS-30 | 8 – 17 | 100 / 200 / 300 | ≥ 25 |
| GMRS-40 | 12 – 28 | 100 / 200 / 300 | ≥ 25 |
| GMRS-70 | 24 – 55 | 100 / 200 / 300 | ≥ 25 |
| GMRS-115 | 40 – 85 | 100 / 200 / 300 | ≥ 50 |
| GMRS-160 | 55 – 122 | 300 / 400 | ≥ 50 |
| GMRS-180 | 60 – 132 | 300 / 400 | ≥ 75 |
| GMRS-200 | 65 – 150 | 300 / 400 | ≥ 75 |
| GMRS-250 | 75 – 192 | 300 / 400 | ≥ 75 |
Applications
- Repair of damaged cable jackets.
- Retrofit protection of connections.
- Connectorized cable repair.
- Used in confined spaces underground and ideal for protections of defrayed cable / connectors.
- Cable / conduit transitions.
- Cable / wire / rope bundles.
- Used in communication, Electrical, Utility, Industrial, Shipboard, Offshore, Marine, Wire and Cable industries.
Technical Specification
| PROPERTIES | VALUE | STANDARD |
|---|---|---|
| Physical | ||
| Tensile Strength | 12 N/mm² (Min.) | ASTM D638 |
| Elongation | 300% (Min.) | ASTM D638 |
| Water Absorption | 0.15% (Max) | ASTM D570 |
| Low Temp. Flexibility | -55°C | ASTM D2671 |
| Specific Gravity | 1.4 | ASTM D792 |
| Longitudinal Change | -10% (Max) | ASTM D638 |
| Flammability | Pass | ASTM D2671 |
| Thermal | ||
| Operating Temperature (Outer Wall) | -55°C to +125°C | IEC 216 |
| Heat Shock | No dripping, cracking or flowing @250°C for 4 hrs | – |
| Chemical | ||
| Fungus Resistance | Inert | MIL-1-7444 |
| Copper Corrosion | Good | ASTM D2671 B |
| Electrical | ||
| Dielectric Strength | > 15 kV/mm | ASTM D2671 |
| Dielectric Constant | 3.0 (Max.) | ASTM D150 |
| Volume Resistivity | 1 x 10¹³ Ohm.cm (Min) | ASTM D257 |
Certificates





FAQs
1. What is a Screened Separable Connector?
A Screened Separable Connector is a medium-voltage cable accessory used to connect power cables to transformers, switchgear, or other equipment. It is fully screened and separable, allowing safe installation, disconnection, and maintenance.
2. What voltage levels are Screened Separable Connectors used for?
They are commonly used for 3.6 kV to 36 kV medium-voltage applications, depending on the connector design and standards.
3. Where are Screened Separable Connectors typically used?
Related Products
Polyolefin Overhead Line Cover
Polyolefin Overhead Line Cover
Polyolefin Overhead Line Cover
Enquiry
109+
Countries
Served
40+
Years
In Industry
1250+
Kw
Solar Generative
225000
Area
Sq ft