Heat Shrink Rain Shed - Tri-core
Home / Heat Shrink Rain Shed – Tri-core
Products
- Heat Shrinkable Joints & Terminations
- Insulation Enhancement Product
- Screened Separable Connectors
- Heat Shrinkable Moulded Shapes
-
Heat Shrink Tubes / Sleeves
- Advantages Of Heat Shrink Tubing
- Thin Wall Tubes
- GDW : Dual Wall Tubing
- Medium/Heavy Wall Tubes-Commercial
- Heat Shrink Co-extruded Tubing Premium Quality
- Red Insulation Tubes
- Non Tracking Tubes
- Busbar Sleeves
- Stress Control Tube
- Non Tracking Tubes
- Integrated Stress Control Tube-GVOT Tube
- Heat Shrink Double Layer Tube-GDTL Tube
- High Shrink Ratio Heat Shrink Tube
-
Switchgear Insulation Products
- Barrier Board Sheet
- End Sealing Kit for Extensible RMU/GIS Bushing
- Heat Shrink Bus Bar Sleeve
- Bus Bar Insulating Shrouds
- Bus Bar Insulating Shrouds Polyolefin
- Bus Bar End Caps
- Thin wall tube wire marking
- Heat Shrink Tape (Bustape)
- Insulation for Circuit Breakers
- Busbar Sleeve for 66 kV
- Bushing Boot
- Non Shrinkable High Voltage Tape
- Heat Shrinkable Gland
- Cable Sealing & Repair Products
- Silicone Overhead Line Cover
- Polyolefin Overhead Line Cover (Insulcover)
- Overhead Line Tube (Insulcover)
- Pipeline / Corrosion / Cathodic Protection Products
- Pole Protection Products
- Wire Harness Products
- New Products
- Miscellaneous
❮
❯
×
Insulshed is used to increase the surface creepage distance of the cores of cable termination without increasing the tail length. They are also used to avoid continuity during rainy season to avoid short circuiting of the electrical network.
The rainsheds are made from high quality cross-linked polyolefin material that offers exceptional non tracking behaviour, insulation and long term service reliability for indoor and outdoor applications. The creepage extension sheds are internally coated with water resistant mastic.
Diagram
Selection Chart
SELECTION CHART
| Gala Code | A (min.) | Ds (±3 mm) | Df (max.) | Hs (min.) | Tf (± 10%) |
|---|---|---|---|---|---|
| GRST-1 | 152 | 35 | 16 | 25 | 2.8 |
| GRST-2 | 45 | 22 | 25 | 33 | 3.0 |
| GRST-3 | 50 | 22 | 25 | 22 | 3.0 |
Technical Specification
Technical Specification
| Properties | Value | standard | |
|---|---|---|---|
| Physical | |||
| Tensile Strength | 12 N/mm² (Mpa) (min.) | ASTM D638 | |
| Ultimate Elongation | 350 % (min) | ASTM D638 | |
| Density | 1.15 ± 0.2 gm/cm³ | ASTM D792 | |
| Hardness | 45 ±10 Shore D | ASTM D2240 | |
| Water absorption | 0.5 % (max.) | ASTM D570 | Thermal |
| Accelerated ageing | (120°C for 500 hrs) | ASTM D2671 | |
| Tensile Strength | 11 N/mm² (Mpa) (min.) | ASTM D638 | |
| Ultimate Elongation | 300 % (min.) | ASTM D638 | |
| Low Temperature Flexibility | No Cracking | ASTM D2671 | |
| (-40 0 C for 4 hrs.) | |||
| Heat Shock (250°C for 30 min.) | No cracking or flowing | ESI 09-11 | |
| Shrink Temperature | 125°C | IEC 216 | |
| Continuous Temperature Limit | -40 to +100°C | IEC 216 | |
| Electrical | |||
| Dielectric Strength | 15 KV/mm. (Min.) | ASTM D149 | |
| Volume Resistivity | 1 x 10¹⁴ Ohm.cm(min.) | ASTM D257 | |
| Dielectric Constant | 5 (Max.) | ASTM D150 | |
| Resistant to track & erosion | No tracking, erosion or flame failure upto 3.25 KV for 20 min. | ASTM D2303 | |