Cable Joints
Home / Cable Joints
Products
- Heat Shrinkable Joints & Terminations
- Insulation Enhancement Product
- Screened Separable Connectors
- Heat Shrinkable Moulded Shapes
-
Heat Shrink Tubes / Sleeves
- Advantages Of Heat Shrink Tubing
- Thin Wall Tubes
- GDW : Dual Wall Tubing
- Medium/Heavy Wall Tubes-Commercial
- Heat Shrink Co-extruded Tubing Premium Quality
- Red Insulation Tubes
- Non Tracking Tubes
- Busbar Sleeves
- Stress Control Tube
- Non Tracking Tubes
- Integrated Stress Control Tube-GVOT Tube
- Heat Shrink Double Layer Tube-GDTL Tube
- High Shrink Ratio Heat Shrink Tube
-
Switchgear Insulation Products
- Barrier Board Sheet
- End Sealing Kit for Extensible RMU/GIS Bushing
- Heat Shrink Bus Bar Sleeve
- Bus Bar Insulating Shrouds
- Bus Bar Insulating Shrouds Polyolefin
- Bus Bar End Caps
- Thin wall tube wire marking
- Heat Shrink Tape (Bustape)
- Insulation for Circuit Breakers
- Busbar Sleeve for 66 kV
- Bushing Boot
- Non Shrinkable High Voltage Tape
- Heat Shrinkable Gland
- Cable Sealing & Repair Products
- Silicone Overhead Line Cover
- Polyolefin Overhead Line Cover (Insulcover)
- Overhead Line Tube (Insulcover)
- Pipeline / Corrosion / Cathodic Protection Products
- Pole Protection Products
- Wire Harness Products
- New Products
- Miscellaneous
Cable Joints- GXLT/GPLT- Series - Heat Shrinkable Straight Through MV Cable Joints & Cable Splicing Kit Suitable for PVC / XLPE/ PILC Cables upto3.3kv
Descriptions : GXLT / GPLT – Series Heat Shrinkable Straight Through Joints (Waterproof) kits designed for 1, 2, 3, 3 & 4 Core extruded Soild dielectric (XLPE/PVC) & paper insulated MV cable joints & Cable Splicing Kit (Armoured / Un-armoured) of 1.1kV & 3.3kV rating.
Guaranteed Technical Particulars in compliance with IEC 60502, 60060 & 60230
| Test Sequence | Parameter for Evaluation | Test Voltage Highest Voltage Umax (Kv) | Result | |
|---|---|---|---|---|
| 1.1 | 3.3 | |||
| Insulation Resistance | 1 min. 500 V DC | — | — | > 10³ Ω |
| A.C. High Voltage Test (Joint Immersed In Water) | 15 min. | 3.5 | 6 | No Breakdown & no Flashover |
| Impulse Witstand Test at Ambient Temperature | 10 Positive & 10 Negative | 8 | 12 | No breakdown & no flashover |
| Insulation Resistance | 1 min. 500 V Dc | — | — | > 10³ Ω |
| Heating Cycle Test in Water (for Straight Through Joint) | 63 cycles 5 hrs. heating & 3 hrs. cooling Conductor temperature 95°C | — | — | No Breakdown & no Flashover |
| Insulation Resistance after Impact Test (Immersed) | 1 min. 500 V Dc | — | — | > 10³ Ω |
| Impulse Withstand Test at Elevated Temperature | 10 Positive & 10 Negative Conductor temperatur 95 to 100° | 8 | 12 | No breakdown & no flashover |
| DC High Voltage Test (Dry) | 5 min. | 15 | 21 | No breakdown & no flashover |
Ordering Informations
| Cable Size | Kit Code | Kit Code |
|---|---|---|
| 4×1.5-6 | GXLT-1 | GXLT-11 |
| 4×10-16 | GXLT-2 | GXLT-12 |
| 4×25-50 | GXLT-3 | GXLT-13 |
| 4×70-150 | GXLT-4 | GXLT-14 |
| 4×185-400 | GXLT-5 | GXLT-15 |
Note :-
- All Kind of Kits are supplied with full kit contents for making a joint.
- Galvanised mesh application is an alternative design replacing wrapparound joint case.
109+
Countries
Served
40+
Years
In Industry
1250+
Kw
Solar Generative
225000
Area
Sq ft