Bus Bar End Caps
Products
- Heat Shrinkable Joints & Terminations
- Insulation Enhancement Product
- Screened Separable Connectors
- Heat Shrinkable Moulded Shapes
-
Heat Shrink Tubes / Sleeves
- Advantages Of Heat Shrink Tubing
- Thin Wall Tubes
- GDW : Dual Wall Tubing
- Medium/Heavy Wall Tubes-Commercial
- Heat Shrink Co-extruded Tubing Premium Quality
- Red Insulation Tubes
- Non Tracking Tubes
- Busbar Sleeves
- Stress Control Tube
- Non Tracking Tubes
- Integrated Stress Control Tube-GVOT Tube
- Heat Shrink Double Layer Tube-GDTL Tube
- High Shrink Ratio Heat Shrink Tube
-
Switchgear Insulation Products
- Barrier Board Sheet
- End Sealing Kit for Extensible RMU/GIS Bushing
- Heat Shrink Bus Bar Sleeve
- Bus Bar Insulating Shrouds
- Bus Bar Insulating Shrouds Polyolefin
- Bus Bar End Caps
- Thin wall tube wire marking
- Heat Shrink Tape (Bustape)
- Insulation for Circuit Breakers
- Busbar Sleeve for 66 kV
- Bushing Boot
- Non Shrinkable High Voltage Tape
- Heat Shrinkable Gland
- Cable Sealing & Repair Products
- Silicone Overhead Line Cover
- Polyolefin Overhead Line Cover (Insulcover)
- Overhead Line Tube (Insulcover)
- Pipeline / Corrosion / Cathodic Protection Products
- Pole Protection Products
- Wire Harness Products
- New Products
- Miscellaneous
Bus Cap is flexible, re-usable, electrical insulating End Cap, used to cover the end of live Bus Bars. These Bus Cap is flexible, re-usable, electrical insulating End Cap, used to cover the end of live Bus Bars. These End Caps can be installed, removed or replaced in few minutes. Made from Polyvinyl Chloride (PVC) material, it is formulated specially for electrical application at high voltage. can be installed, removed or replaced in few minutes. Made from Polyvinyl Chloride (PVC) material, it is formulated specially for electrical application at high voltage.
Standards
- Tested to ANSI C 37.20.2 Standards for medium voltage switchgear application to 36KV.
Features and Benefits
- Provide significant reduction in air clearances.
- Excellent electrical, mechanical & thermal properties.
- Highly resistant to UV rays and ozone. Good for indoor or outdoor applications.
- Customised design & Colours can be developed in a week.
Diagram
Selection Chart
| Gala Code | MM | A MM | W MM | L MM |
|---|---|---|---|---|
| GBC1 | 15 x 5 | 15 | 5 | 20 |
| GBC2 | 20 x 5 | 20 | 5 | 20 |
| GBC3 | 25 x 5 | 25 | 5 | 20 |
| GBC4 | 30 x 10 | 30 | 10 | 30 |
| GBC5 | 40 x 10 | 40 | 10 | 30 |
| GBC6 | 50 x 6 | 50 | 6 | 30 |
| GBC7 | 50 x 10 | 50 | 10 | 30 |
| GBC8 | 60 x 10 | 60 | 10 | 30 |
| GBC9 | 65 x 8 | 65 | 8 | 30 |
| GBC10 | 75 x 6 | 75 | 6 | 50 |
| GBC11 | 80 x 10 | 80 | 10 | 50 |
| GBC12 | 100 x 6 | 100 | 6 | 50 |
| GBC13 | 100 x 10 | 100 | 10 | 50 |
| GBC14 | 100 x 24 | 100 | 24 | 50 |
| GBC15 | 120 x 10 | 120 | 10 | 50 |
| GBC16 | 125 x 10 | 125 | 10 | 50 |
| GBC17 | 150 x 6 | 150 | 6 | 70 |
| GBC18 | 200 x 12 | 200 | 12 | 70 |
Technical Specification
| Test Description | Recorded Value | Test Method |
|---|---|---|
| Dielectric Strength | 12 KV/mm. (min.) | ASTM D149 |
| Tensile Strength | 12 N/mm² (min.) | ASTM D638 |
| Elongation | 350% (min.) | ASTM D638 |
| Density | 1.23 gm/cm³ | ASTM D792 |
| Hardness | 65 ± 5 Shore A | ASTM D2240 |
| Continuous Operating Temp. | -20°C to 115°C | IEC 216 |
| Flammability | Pass | UL 94-V0 |
Certificates





FAQs
1. What is a Screened Separable Connector?
A Screened Separable Connector is a medium-voltage cable accessory used to connect power cables to transformers, switchgear, or other equipment. It is fully screened and separable, allowing safe installation, disconnection, and maintenance.
2. What voltage levels are Screened Separable Connectors used for?
They are commonly used for 3.6 kV to 36 kV medium-voltage applications, depending on the connector design and standards.
3. Where are Screened Separable Connectors typically used?
Related Products
Polyolefin Overhead Line Cover
Polyolefin Overhead Line Cover
Polyolefin Overhead Line Cover
Enquiry
109+
Countries
Served
40+
Years
In Industry
1250+
Kw
Solar Generative
225000
Area